Disclosure: some links below are Amazon affiliate links. If you buy through them, Home Air Lab may earn a small commission at no extra cost to you.
You turn on the range hood every time you sear a steak. Here is the uncomfortable part: depending on the hood, it may be catching less than 15% of the pollution coming off your gas burners, or more than 98%. Researchers at Lawrence Berkeley National Laboratory measured that spread, and it does not line up with price.
What Berkeley Lab found
In a lab study by Delp and Singer, seven representative under-cabinet hoods priced from $40 to $650 were tested for capture efficiency, meaning the share of cooking pollutants that actually gets pulled out instead of drifting into the room. Capture ranged from under 15% to over 98%. Price did not guarantee performance, and few hoods did well on all three measures the team looked at: capture, quietness and energy use.
Two points stand out:
- Back burners beat front burners. Every hood captured pollutants from the two back burners better than from the front ones. Hoods that met the airflow recommendations in the ventilation standard HV1 captured roughly 80% or more from the back burners, 60% or more from the oven, and 50% or more from the front burners.
- ENERGY STAR did not mean good capture. The two ENERGY STAR-rated hoods in the study captured less than 30% of front-burner and oven pollutants. At the time, the rating covered energy use and noise, not capture efficiency.
Open-style hoods also did better than those with grease screens or metal-covered undersides, and the one large open hood that exceeded 80% on the front burners was too loud for normal conversation.
Why it matters in a real kitchen
A separate Berkeley Lab analysis estimated that in a typical California winter week, about 60% of homes that cook with a gas stove at least once a week could reach pollutant levels that would be illegal outdoors, including nitrogen dioxide, formaldehyde and carbon monoxide. The lead researcher said that if every affected home had a hood that vents outdoors and works even moderately well, the number of homes over those standards would drop by more than half. A study of 15 installed hoods also found that real-world airflow was often below the advertised figure, and in many cases less than half of gas-burner pollutants were removed.
One honest caveat from the researchers: they had not yet confirmed that these capture results hold for frying and stir-frying, as opposed to gas-burner emissions.
What to do about it
- Cook on the back burners whenever the recipe allows it.
- Run the fan every time you cook, on the highest setting you can tolerate, and for a few minutes afterward.
- Vent outdoors. A hood that recirculates air back into the kitchen does not remove gas combustion pollutants.
- Shopping for a new hood? Berkeley Lab advises at least 200 cubic feet per minute (CFM), and ideally a model that has been tested for capture efficiency, not just noise and energy use. Browse vented range hoods rated 200+ CFM and check the airflow rating before you buy.
- Open a window or run make-up air if your kitchen is tight, so the fan is not fighting a vacuum.
If you cannot vent outdoors
A portable HEPA air purifier with activated carbon will not replace a good vented hood, and it does not remove combustion gases like nitrogen dioxide. It can help reduce fine particles lingering after you cook, so treat it as a supplement and size it to the room.
The bottom line
Check your hood’s actual airflow, use the back burners, and run the fan every time. Those three habits cost nothing, and they are what the Berkeley Lab data supports.
Sources
- Lawrence Berkeley National Laboratory, Berkeley Lab study assesses residential cooking exhaust hoods’ ability to vent pollutants (2012)
- Lawrence Berkeley National Laboratory, Pollution in the Home: Kitchens Can Produce Hazardous Levels of Indoor Pollutants (2013)
Follow @homeairlab on Instagram for short, sourced air-quality videos.